Standard views

Status: available.

What it is

Each standard view sets up the plots for one common inspection task in a single step, using the axes, quantity and averaging that the task needs. Every setting can be changed afterwards. Each view has a short description that the window shows on request.

What it is for

These views are the usual first pass over a new observation. Each corresponds to a display that AIPS or CASA users already know:

View

Python preset=

Shows

Like

Amplitude survey

"vplot"

Baseline × Time amplitude raster, with amplitude against time

AIPS VPLOT, TVFLG

Radial plot

"radplot"

the same raster, with amplitude against UV distance

AIPS RADPLOT, plotms amp vs uvdist

Waterfall

"waterfall"

Time × Channel amplitude, one baseline

AIPS SPFLG

Phase waterfall

"phase-waterfall"

Time × Channel phase, one baseline

AIPS SPFLG in phase

All-baseline waterfall

"waterfall-all"

every selected baseline in one Time × Channel image, each cell its largest amplitude

AIPS FTFLG

Z-Score survey

"zscore"

Baseline × Time colored by Z-Score

Phase stability

"phaserms-time", "phaserms-freq", "phaserms-uvdist"

Phase RMS against time, channel or UV distance

Antenna matrix

"antmatrix"

Antenna × Antenna, one cell per baseline, averaged over the selection

AIPS LISTR matrix

Spectrum

"spectrum"

amplitude above phase against frequency, each scan averaged

AIPS POSSM, plotms bandpass views

Time series

"timeseries"

amplitude above phase against time, all channels averaged

AIPS VPLOT

How it behaves

  • How each view’s values are computed. Each view is an ordinary plot, so its values follow How it is calculated and How it is calculated. In particular:

    • the antenna matrix averages each baseline over the whole selection;

    • the all-baseline waterfall combines baselines by maximum (baseline_combine="max");

    • the spectrum and time series use scatter averaging.

  • A suggested order for commissioning:

    1. Survey with the antenna matrix, Z-Score, phase stability and amplitude views. In the antenna matrix, an antenna that is bad on every baseline is a whole row and column.

    2. Confirm on single baselines with the waterfalls, the spectrum and the time series, stepping through baselines.

    3. Flag on whichever view shows the problem best.

    The steps are described in A commissioning workflow in The visplot window.

  • A view normally switches to the layout that suits it. The layout can be pinned, so that views change only the plots and not their arrangement.

From Python

visplot(vis="obs.ms", preset="antmatrix")
visplot(vis="obs.ms", preset="spectrum", antenna="EA01&EA02")
visplot(vis="obs.ms", preset="vplot", pin_layout=True, layout="one")

Limits

  • Flag boxes are refused on the antenna matrix. Find the antenna there, then flag it on a Baseline × Time view.


Coming from plotms or AIPS? See Coming from plotms and Coming from AIPS.